1Differential pressure (ΔP)

The pressure difference between two points. It is what makes fluid flow.

2Easy definition, and a picture to remember

In one line

Differential pressure, written ΔP (delta P), is the pressure at one point minus the pressure at another, for example before and after a valve.

Imagine it

Picture two water tanks joined by a pipe. Water moves from the fuller tank to the emptier one, and the bigger the difference in level, the faster it flows. It is the difference that matters, not how full each tank is.

Memory hook

Flow needs a driving pressure difference (or head). To double the flow you need four times the ΔP.

3What changes it, and how

Three things set how much ΔP a valve or pipe uses up.

1

Flow rate

Pushing more fluid through a restriction takes more pressure.

Double the flow and the ΔP becomes four times larger.

ΔP ∝ Q²

2

Size of the opening

A smaller opening is harder to push through.

A more closed valve has a lower Kv and needs a bigger ΔP for the same flow.

ΔP = SG · (Q / Kv)²

3

Fluid density

A heavier fluid needs more push to move at the same speed.

A denser liquid gives a higher ΔP for the same flow and opening.

SG = ρ / ρ_water

Try it: pressure difference drives flow

To double the flow through a valve, how much more pressure difference do you need?

P₁05105.0barP₂05104.0barΔP 1.0 barNarrow gap, faster flow

Fluid flows from high pressure to low pressure. Try ΔP = 1 bar, then 4 bar: the flow only doubles.

5Units and formulas

ΔP has no “g” or “a”. It is the same whether you use gauge or absolute pressures. Often written in bar, kPa, mbar or psid.

Formulas

  • ΔP = P₁ − P₂
  • Q = Kv · √(ΔP / SG)
  • ΔP = SG · (Q / Kv)²

Convert a pressure

bar
1
kPa
100
MPa
0.1
psi
14.504
atm
0.9869
kgf/cm²
1.02
mWC
10.197

Write bar(g) for gauge and bar(a) for absolute so nobody has to guess which one you mean.

6Why it matters, and common mistakes

Why it matters

  • ✓Valve sizing starts from the pressure drop available.
  • ✓A rising ΔP across a strainer warns that it is clogging.
  • ✓Pump head is differential pressure written as a height.

Common mistakes

  • !Swapping upstream and downstream, which flips the sign.
  • !Adding or subtracting gauge and absolute readings. Use the same kind for both points.
  • !Assuming flow is proportional to ΔP. It follows the square root.