The question it answers
Classification by how it is operated
Who or what moves the valve?
A valve does nothing until something moves its stem. That something can be a person's hand, a gearbox that multiplies the hand's force, or a motor or air supply taking commands from a control system. The choice sets how fast, how often and how remotely the valve can be used.
1The options in detail
Handwheel or lever
A person turns a wheel or swings a lever on the valve itself.
Far side: 6.0 barDrag to rotate · hover a dot for its name
How it works
The handwheel turns a threaded stem on linear valves. A lever turns a quarter-turn valve directly. A lever's position tells you the valve's position.
Strengths
- ✓Cheapest and simplest.
- ✓Needs no power.
- ✓Position is easy to see.
Limits
- !Needs a person at the valve.
- !Slow for large linear valves.
- !Hard to reach valves are rarely operated.
Where it is used
- •Maintenance isolation.
- •Small and medium valves.
- •Places with no power.
Gearbox
A gear set between the handwheel and the stem multiplies the force.
Far side: 6.0 barDrag to rotate · hover a dot for its name
How it works
A worm gear trades many turns of the handwheel for a quarter turn of the stem with a large increase in torque. It also locks the position, so line forces cannot back-drive the valve.
Strengths
- ✓Lets one person operate a large valve.
- ✓Usually self-locking (depends on the gear design), holds position.
- ✓Position indicator on the gearbox.
Limits
- !Slower than a lever.
- !Adds cost and weight.
- !Needs occasional greasing.
Where it is used
- •Large butterfly and ball valves.
- •Buried and valve-chamber valves with extension spindles.
- •Large gates in water pipes.
Actuated (electric, pneumatic, hydraulic)
A motor or a piston moves the valve on a command from a control system.
Far side: 6.0 barDrag to rotate · hover a dot for its name
How it works
An electric actuator uses a motor and gears. A pneumatic one uses air pressure on a piston or diaphragm. A hydraulic one uses oil. All can report the valve position back to the control room.
Strengths
- ✓Remote and automatic operation.
- ✓Fast, repeatable.
- ✓Position feedback and interlocks.
Limits
- !Needs power, air or hydraulic supply.
- !Higher cost and maintenance.
- !Must be sized for the maximum torque, not the average.
Where it is used
- •Plant automation and remote sites.
- •Emergency shutdown valves.
- •Pipelines with many valves.
Fail-safe
An actuator that moves the valve to a safe position by itself when power, air or signal is lost.
Far side: 6.0 barDrag to rotate · hover a dot for its name
How it works
A spring is compressed while the actuator is working. If the supply fails, the spring pushes the valve to the chosen safe position: closed, open or, with some designs, where it was.
Strengths
- ✓Goes safe with no power and no operator.
- ✓Required for many safety functions.
- ✓Simple spring return in pneumatic actuators.
Limits
- !Bigger, as the spring and supply must both be accommodated.
- !The safe position must be chosen carefully.
- !Needs regular partial-stroke testing.
Where it is used
- •Emergency shutdown and fire isolation.
- •Boiler, burner and fuel lines.
- •Any duty where the safe position is clear.
How to choose
- →Occasional, local use: handwheel or lever.
- →Large manual valve: gearbox.
- →Remote, frequent or automatic: actuator.
- →A failure must make the plant safe: fail-safe actuator, with the safe direction decided by the process.
Common mistakes
- !Choosing fail-open when the safe position is closed, or the reverse.
- !Sizing the actuator for the running torque, not the breakaway torque.