The question it answers
Classification by special duty
Check valves built for a particular job.
Some jobs need more than one-way flow. A pump that sucks water up from a well must stay primed. A boiler has to be isolated by hand as well as protected. A wastewater outfall needs a valve with nothing that can jam.
1The options in detail
Foot valve
A lift check with a strainer, at the bottom of a suction pipe.
How it works
It sits under the water at the lower end of the pipe. The strainer keeps debris out, and the disc lifts when the pump sucks and drops when it stops, so the pipe stays full and the pump stays primed.
Strengths
- ✓Keeps the pump primed.
- ✓The strainer protects the pump.
- ✓Simple.
Limits
- !The strainer can clog.
- !Adds suction loss.
Where it is used
- •Wells and tanks.
- •Pumps above the water level.
Stop-check
A lift check with a handwheel that can hold it shut.
How it works
While the stem is wound up it works as an automatic check valve. Wound down, the stem presses the disc onto its seat, so it also isolates. It is common on boiler feed lines, where the boiler must be shut off as well as protected.
Strengths
- ✓Automatic and manual in one.
- ✓Prevents backflow.
- ✓Allows isolation.
Limits
- !High pressure drop.
- !More complex.
Where it is used
- •Boiler feedwater.
- •Steam lines.
Duckbill check
A rubber sleeve that ends in two lips.
How it works
There are no moving parts. The flow parts the soft lips, and any back pressure squeezes them together. The rubber flexes, so it seals round trapped debris.
Strengths
- ✓No hinge or spring to jam.
- ✓Handles solids.
- ✓Little maintenance.
Limits
- !Limited pressure and temperature.
- !Rubber ages.
Where it is used
- •Wastewater outfalls.
- •Drains into rivers and the sea.
How to choose
- →Pump suction from below the water level: foot valve.
- →A boiler or line that must also be isolated: stop-check.
- →Outfalls and dirty drains: duckbill.
Common mistakes
- !Forgetting to clean a foot-valve strainer.
- !Expecting a stop-check to relieve pressure.
- !Using a duckbill outside its pressure rating.