Gate valves
A straight-through door for the flow: fully open or fully shut.
Step 6 of 7
6Calculations
These use your duty, the construction and the materials from the earlier steps, so nothing is typed again. Each result shows its formula, and a pass or CHECK mark. Change a value here only if you know better than the default.
1. Pressure drop and velocity
Kv = 0.04·DN² / √ζ · ΔP = ζ·ρ·v² / 2 · v = Q / A
- Density
- 1,000 kg/m³
- Velocity
- 3.54 m/s
- ζ
- 0.15
- Kv
- 4,131 m³/h
- ΔP
- 0.009 bar
- !The line velocity is above the usual limit for this service. Check the pipe size, or accept more noise, erosion and pressure loss.
The loss coefficient is a typical textbook value. Fully open it is reliable, but published figures for a part-open gate differ between sources by up to two or three times. For anything that depends on the part-open loss, use the manufacturer's Cv curve.
2. Stem load and how to operate it
F = ΔP·π/4·D² · thrust = (μ·F + W)·SF · T = thrust·lead / (2π·η)
- Friction between wedge and seat
- 0.20
- Force of the pressure on the gate
- 31.4 kN
- Thrust needed
- 9.9 kN
- Stem torque
- 42 N·m
- Stem turns, open to closed
- 28
- Rim pull on the handwheel
- 227 N
How to operate it
Handwheel
One person can operate it: the rim pull is within about 360 N.
3. Closing time and water hammer
tcrit = 2L / a · ΔP = ρ·a·Δv (t ≤ tcrit) · ΔP ≈ 2·ρ·L·Δv / t (Michaud)
- Wave speed
- 1000 m/s
- Closing time
- 41 s
- Critical time 2L/a
- 1.0 s
- Estimated surge
- 0.9 bar
- Allowed surge (assumed: 10 % of design pressure, a rule of thumb)
- 1.0 bar
- Shortest safe closing time
- 35 s
Typical – not brand data. This is a pre-selection. Confirm the final choice with the manufacturer and the project specification.