Lift check valves
A disc or piston that the flow lifts straight off its seat and gravity or a spring drops back.
Lift check valves are classified in several ways at once: by the moving part, by the spring, by the body, and by the seat. Each option below has its own 3D cutaway.
11. By moving part: disc or piston
The moving part is either a disc on a stem or a piston in a sleeve. The piston is the version for pulsating flow.
Disc
A conical disc on a stem that slides in a guide bush in the cover.
How it works
The disc rises on its stem as the flow lifts it. Small wings under the disc keep it centred in the seat.
Strengths
- ✓Simple.
- ✓Low loss for a lift check.
- ✓Easy to repair.
Limits
- !Chatters in pulsating flow.
- !Needs a steady flow.
Where it is used
- •Steady flows.
- •Steam and clean liquids.
Piston
A tall piston that runs in a close-fitting sleeve in the cover.
How it works
The piston rises in its sleeve and traps a little fluid above it, which cushions each movement. It rides out pulses without chattering.
Strengths
- ✓Stands up to pulsating flow.
- ✓Smooth, cushioned closing.
- ✓Long life on reciprocating pumps.
Limits
- !A little more loss.
- !The sleeve can stick on dirty fluids.
Where it is used
- •Reciprocating pumps.
- •Compressors and dosing lines.
22. By spring: gravity, light or heavy
The spring decides how much flow it takes to hold the disc lifted, and how fast it closes. Without a spring the disc closes by weight and the valve must be fitted with the cover up.
Gravity only
No spring: the disc drops back by its own weight.
How it works
The disc is heavy enough to fall back on the seat once the flow stops. It must be fitted with the cover up.
Strengths
- ✓Simplest.
- ✓The lowest cracking pressure.
Limits
- !Horizontal lines only, or flow upward.
- !Slowest to close.
Where it is used
- •Horizontal water, oil and steam lines.
Light spring
A weak coil that helps the disc down.
How it works
The spring lets the valve be fitted in any position and closes the disc a little faster than gravity.
Strengths
- ✓Any position.
- ✓A low cracking pressure.
Limits
- !A little more flow needed to hold open.
Where it is used
- •Vertical lines.
- •Most general service.
Heavy spring
A strong coil: the fastest close and the least slam.
How it works
The strong spring pushes the disc down at once when the flow stops, so there is almost no reverse flow.
Strengths
- ✓The fastest close.
- ✓The least slam.
Limits
- !Needs more flow to hold open.
- !A higher cracking pressure.
Where it is used
- •Fast pump stops.
- •Gas and compressor lines.
33. By body: bolted cover, pressure seal or forged
The body decides the pressure and temperature the valve can take, and how the cover is held on.
Bolted cover
The cover is held on the body by studs and nuts, with a gasket between.
How it works
The cover carries the guide bush and can be taken off to reach the disc and the seat without removing the body from the line.
Strengths
- ✓Easy to repair in the line.
- ✓Every size and normal rating.
Limits
- !The gasket joint can leak at very high pressure.
Where it is used
- •Process plants.
- •Water and oil lines.
Pressure seal
A cover that the pressure itself pushes into the body, held by a segmented ring.
How it works
A metal seal ring is squeezed against the body by the pressure behind it. The higher the pressure, the tighter it seals.
Strengths
- ✓Tight at very high pressure and temperature.
- ✓No large bolted flange.
Limits
- !Dearer.
- !Harder to take apart.
Where it is used
- •Power plants.
- •Boiler feed and steam lines.
Forged
A small body forged from solid steel, with socket-weld or threaded ends.
How it works
The body is forged in one piece and its cap is welded or screwed on. It is compact and strong.
Strengths
- ✓Very strong and compact.
- ✓Few leak points.
- ✓Cheap in small sizes.
Limits
- !Small sizes only (usually up to DN 50).
- !Cannot be opened if welded.
Where it is used
- •Small high-pressure lines.
- •Instrument and chemical lines.
44. By seat: metal or resilient
The seat is what the disc closes on. It decides the tightness and the temperature the valve can take.
Metal seat
Metal on metal, with a hard-faced band on the disc and seat.
How it works
The conical face of the disc closes on a hard band in the seat. It takes heat and does not wear in clean fluids.
Strengths
- ✓Takes high temperature.
- ✓Very hard-wearing.
- ✓Fire-safe by nature.
Limits
- !Leaks a little.
- !Grit can stop it sealing.
Where it is used
- •Steam and hot oil.
- •High pressure.
Resilient seat
A rubber face on the disc presses into the seat.
How it works
The soft face presses into the metal and fills the tiny gaps, so the valve seals drop-tight.
Strengths
- ✓Drop-tight sealing.
- ✓Seals on a little grit.
Limits
- !Limited in temperature and fluid.
- !The rubber can wear or swell.
Where it is used
- •Water lines.
- •Low-pressure gas.
Metal (13 % chrome or bronze)
A plain metal seat for water, oil and gas. It is hard and cheap and allows a small leak.
Water, oil, gas
Hard-faced metal
A harder alloy overlay for high temperature, steam and abrasive fluids.
Steam, hot oil, wear
EPDM rubber
A rubber face for hot and cold water and many chemicals. Not for oils.
Water, air, dilute chemicals
NBR (nitrile)
A rubber face that stands up to oils and fuels. Limited in heat.
Oils, fuels, gas
FKM (fluoroelastomer)
A rubber for hot oils and many chemicals. Dearer than EPDM or NBR.
Hot oils, chemicals
55. Disc and stem materials
The disc, stem and seat are wet by the fluid and rub against each other, so their material matters as much as the body.
Bronze
Good for fresh water and mild service. Not for seawater, strong chemicals or steam.
Fresh water
Stainless steel 304
A general-purpose stainless steel for water, air and many fluids.
Water, air, food
Stainless steel 316
Stainless steel with better resistance to chloride and chemicals.
Seawater, chemicals
Duplex stainless steel
Stronger and more resistant to chloride cracking. For harsh and high-pressure service.
Seawater, sour service
66. Standards
These are the main standards a specification or datasheet refers to.
| Standard | Covers | Typical use |
|---|---|---|
| BS 1868 / API 594 | Steel check valves: flanged and butt-welding | Process plants and power plants |
| API 602 / BS 5352 | Small forged-steel valves, including lift checks | Small high-pressure lines |
| ASME B16.34 | Pressure-temperature ratings of valves | Rating selection |
| API 598 / EN 12266 | Shell and seat tests, and leakage classes | Acceptance testing |
| ASME B16.10 | Face-to-face and end-to-end lengths | Checking the length against the pipe |
Check the current edition and the project specification: they decide which standard applies.
77. Why this model and not another?
A lift check is the strong, tight choice for small, high-pressure and steam lines, but its loss is high. Here is how to choose.
| If your duty is… | Lift | Nozzle | Swing check | Dual-plate |
|---|---|---|---|---|
| Small line, high pressure | Best choice | Good | Fair | Fair |
| Steam or hot oil | Best choice | Fair | Good | Poor |
| Pulsating flow (reciprocating pump) | Best choice: piston type | Fair | Poor | Poor |
| Water or sewage with solids | Poor: jams the disc | Poor | Best choice | Poor |
| Large line, low loss wanted | Poor: high loss | Good | Good | Fair |
| Pump that may stop fast | Fair: spring type | Best choice | Needs lever and dashpot | Good |
| Vertical line, flow up | Good: with a spring | Good | Good | Good |
Choose a lift check when…
Choose it when
- ✓The line is small.
- ✓The pressure or temperature is high.
- ✓The flow pulses (use a piston type).
- ✓You want a simple, tight valve.
Do not choose it when
- ✗Solids, sewage or slurry.
- ✗A large line where the loss matters.
- ✗A low-head line that cannot spare the pressure.
Choose a swing check when…
Choose it when
- ✓The fluid has solids.
- ✓You want a clear bore and low loss.
- ✓The line is large or low-pressure.
Do not choose it when
- ✗Pulsating flow.
- ✗Fast pump stops with no aid.
Choose a nozzle or dual-plate when…
Choose it when
- ✓The pump can trip and a surge would harm the line.
- ✓You want a low-slam valve in a clean line.
Do not choose it when
- ✗Solids and sewage.
- ✗Pulsating flow.
Common mistakes
- !Fitting a spring-less lift check in a vertical line with the flow down: the disc will not close.
- !Using it on sewage: rags stop the disc seating.
- !Forgetting the pressure drop: the flow must be high enough to hold the disc fully lifted, and then the loss is high.
- !Using a plain disc on a reciprocating pump: the pulses make it chatter and wear. Use a piston type.
- !Choosing the size at the pipe size: at low flow the disc hardly lifts and flutters.
💡 Rule of thumb: lift check for small, high-pressure, steam and pulsating lines; swing check where there are solids or a clear bore is needed; nozzle or tilting disc for large, fast-stopping lines.