← Non-return valves

Swing check valves

A hinged disc that the flow pushes open, and that swings shut by itself when the flow stops.

Learn sizing

Seven short lessons take you from "is a swing check right for my line?" to a finished selection. Each has a drawing and a calculator you can play with. Nothing here is saved or sent.

  1. 1. Is a swing check the right check valve?
  2. 2. How the disc moves
  3. 3. Loss and size
  4. 4. Body, parts and rating
  5. 5. Seats and trim
  6. 6. Slam and the closing surge
  7. 7. Choosing the closing aid

1Is a swing check the right check valve?

A swing check is the first choice for steady liquid flow with solids or low loss. It is not for pulsating flow, and in long pump lines it needs help to close.

  • ✓Water, raw water, sewage and oil at steady flow: yes.
  • ✓Reciprocating pumps and pulsating flow: no, use a ball or lift check.
  • ✓Pump lines that stop fast: add a lever and dashpot, or use a nozzle or tilting disc check.
  • ✓Compact, light installations: a dual-plate or wafer check.
Forward flowDrag to rotate · hover a dot for its name

A swing check with a plain, gravity-closed disc.

Try it

Fluid

Good fitExternal hingeLever and dashpotWafer

Clean liquid at a steady flow is the swing check's best duty: low loss and a long life.

💡 Ask first how the flow starts and stops. A swing check is easy to choose and easy to get wrong in a long pump line.

2How the disc moves

The disc hangs from the hinge. Flow pushes it up and it stays open while the flow is fast enough. At low flow it hangs part-open and flutters against the stop, wearing the hinge and seat.

  • ✓The flow must reach a minimum velocity to hold the disc fully open.
  • ✓A heavier fluid holds it open at a lower speed.
  • ✓At low flow the disc flutters and the loss climbs.
  • ✓An outside lever lets you see the disc position.

v_min = 0.3048 · 35 · √V V = 16.018 / ρ (ft³/lb, ρ in kg/m³)

Internal hinge

Forward flowDrag to rotate · hover a dot for its name

External hinge

Forward flowDrag to rotate · hover a dot for its name

Left: an internal hinge. Right: a through pin with an outside indicator.

Try it

Velocity
1.89 m/s
Minimum velocity to hold it open
1.35 m/s
How far the disc is held open
100 %
ζ
2.00

OKThe flow is enough to hold the disc fully open.

The rule of thumb is v = 35·√V in ft/s, where V is the specific volume. Below this speed the disc is not held fully open, so it flutters against its stop and the loss climbs.

💡 Choose the valve for the flow it will really carry. A valve at the pipe size can be too big for a low flow.

3Loss and size

A swing check loses a little pressure even when fully open. The loss grows with the square of the speed, and rises steeply if the disc is not held open.

  • ✓A full-bodied swing check has ζ of about 2 when fully open.
  • ✓A wafer or pressure-seal body is a little higher.
  • ✓Keep the speed below the limit for the fluid.
  • ✓Size the valve to the flow, not just the pipe.

Kv = 0.04 · DN² / √ζ Cv = 1.156 · Kv ΔP = ζ · ρ · v² / 2

Forward flowDrag to rotate · hover a dot for its name

A wafer swing check between the flanges.

Try it

Velocity
3.14 m/s
Bolted cover
ζ 2.00 · ΔP 0.099 bar
Wafer
ζ 2.40 · ΔP 0.12 bar
Pressure seal
ζ 2.60 · ΔP 0.13 bar

Typical figures. A wafer or pressure-seal body is slimmer, so it loses a little more than a full bolted-cover body.

💡 If the disc cannot be held open, a smaller valve is better than a bigger one with the pipe reduced around it.

4Body, parts and rating

A swing check is built with a bolted cover, as a wafer, or with a pressure-seal cover. Know the parts and you can read any datasheet. The rating is the highest pressure at a given temperature.

  • ✓Bolted cover: serviced in line, every size.
  • ✓Wafer: light and cheap, for small sizes and low pressure.
  • ✓Pressure seal: for very high pressure and temperature.
  • ✓The rating comes from the body and the seat together.
CombinedDrag to rotate · hover a dot for its name

Typical – not brand data. Materials vary by manufacturer, size, class and service.

Every part of the valve, with its typical material in the list below.

Try it

Class 300 (46.0 bar)

Resilient seats usually limit the class: EPDM and NBR seats are normally used up to Class 300.

💡 Check the maker's pressure-temperature table: a rubber seat usually limits the class to 300 and about 100 °C.

5Seats and trim

The seat is what the disc closes on. A metal seat is strong and takes heat but leaks a little. A rubber-faced disc seals drop-tight but is limited in temperature and fluid.

  • ✓Metal: steam, oil, hot water, dirty fluids.
  • ✓Hard-faced: very hot or erosive duty.
  • ✓EPDM: water and sewage; NBR: oil and gas; FKM: chemicals.
  • ✓Bronze trim for fresh water; stainless or duplex for seawater and chemicals.
Forward flowDrag to rotate · hover a dot for its name

A rubber-faced seat.

Try it

  • Metal (13 % chrome or bronze)Suited
  • Hard-faced metalSuited
  • EPDM rubberSuited
  • NBR (nitrile)Suited
  • FKM (fluoroelastomer)Not suitednot suited to this fluid

A rubber seat seals drop-tight but is limited in temperature and fluid. A metal seat takes the heat but leaks a little.

💡 If the fluid is dirty, a rubber face seals past small grit; a metal seat can be held off by it.

6Slam and the closing surge

When the pump stops, the flow slows, stops and then runs back. A disc that is still open when the flow reverses is slammed shut, and the sudden stop sends a pressure wave along the pipe.

  • ✓The longer and the lower the pressure, the slower the flow stops.
  • ✓A disc that closes sooner has less reverse flow.
  • ✓A dashpot cushions the last part of the swing.
  • ✓Always check this for pump lines with liquids.

a = (P / ρ) / L (not above v / 0.5) v_rev = a · t_close ΔP = ρ · c · v_impact

Forward flowDrag to rotate · hover a dot for its name

A plain disc, closed by gravity.

Try it

How fast the flow slows
2.00 m/s²
Time for the disc to swing shut
0.24 s
Velocity at impact (after cushioning)
0.49 m/s
Closing surge
4.9 bar

CHECKThe disc hits the seat hard: add a closing aid.

💡 In a long pump line with a fast stop, a plain swing check slams. A lever and dashpot, a nozzle check or a tilting disc check closes before the flow reverses.

7Choosing the closing aid

A lever and weight pulls the disc shut sooner. A dashpot cushions the last part of the swing. Pick the lightest aid that keeps the surge within the allowed value, and check that it still opens at your flow.

  • ✓None: simple, for short lines and gentle stops.
  • ✓Weight: closes sooner, raises the holding velocity.
  • ✓Dashpot: cuts the impact a lot, adjustable.
  • ✓Very fast stops need a different valve type.

Lever and weight

Forward flowDrag to rotate · hover a dot for its name

Lever and dashpot

Forward flowDrag to rotate · hover a dot for its name

Left: lever and weight. Right: lever and dashpot.

Try it

  • No aid (gravity)2.9 barCHECKMinimum velocity to hold it open: 1.35 m/s
  • Lever and weight1.8 barCHECKMinimum velocity to hold it open: 1.62 m/s
  • Lever and dashpot0.7 barOKMinimum velocity to hold it open: 1.49 m/s

Each aid is set against the allowed closing surge. A weight raises the flow needed to hold the disc open, so check that too.

💡 Add the aid for the worst case: a pump trip, not a gentle stop.

Ready to size your valve?

Enter your duty once and the next pages decide if a swing check suits it, choose the hinge, closing aid and body, pick the seat and materials, read off the rating, and check flow, holding velocity and closing surge.

Start with the duty →