1Kv and Cv
How valve capacity is expressed, and how to convert between Kv and Cv.
2Easy definition, and a picture to remember
Kv is the flow of water, in m³/h, that a valve passes with a pressure drop of 1 bar. Cv is the same idea in US units: gallons per minute of water at 1 psi. A bigger Kv means a valve that passes more.
Imagine it
Think of a tap. Open it fully and fill a bucket: the litres per minute are the tap's capacity. Kv is that number, measured the same way for every valve: with water, under a fixed 1 bar push. It lets you compare a valve from one maker with a valve from another.
| Valve | Kv | Flow | Litres per minute | Time to fill 10 L |
|---|---|---|---|---|
| Valve A | 6 | 6.0 m³/h | 100 | 6.0 s |
| Valve B | 18 | 18.0 m³/h | 300 | 2.0 s |
Q = Kv × √(ΔP / SG) = 6 × √(1.00 / 1) = 6.0 m³/h
This is the standard test: 1 bar across the valve. At 1 bar the flow in m³/h is exactly the Kv, which is why Kv works as a capacity number.
Valve B has 3.0 times the Kv of valve A, so at the same push it passes 3.0 times the flow and fills the bucket in 1/3.0 of the time.
Every valve is tested the same way: fully open, with water, with a fixed 1 bar across it. The litres it passes are its capacity, and the figure is the Kv. The gauge before the valve reads the supply pressure; the one after reads what is left. Their difference is the push. That makes valves from different makers comparable.
Memory hook
Kv: m³/h of water at 1 bar. Cv: gpm at 1 psi. Cv = 1.156 × Kv.
3What decides it, and how
Three things decide the flow through a valve with a given Kv.
Pressure drop
More push gives more flow, but only by a square root.
Four times the drop gives only twice the flow.
Q = Kv · √(ΔP / SG)
Opening
Kv grows as the valve opens, along a curve set by the valve's characteristic.
At 50% opening a linear valve passes 50% of its Kv. An equal-percentage valve passes about 14%.
Kv = Kvs · f(opening)
The liquid
A heavier liquid flows less for the same push.
Brine (SG 1.2) passes about 9% less than water.
SG = ρ / ρ_water
Try it: throttle a valve and see the flow follow Kv
A valve passes 10 m³/h of water with a 1 bar pressure drop. What is its Kv?
- Kv at this opening
- 50.0 m³/h
- Cv at this opening
- 57.8
- Flow
- 50.0 m³/h
- Flow in US units
- 220 gpm
Throttled: the narrower gap passes less. The flow follows Kv and the square root of the drop.
5Units and formulas
Kv is in m³/h (water, 1 bar). Cv is in US gpm (water, 1 psi). Cv = 1.156 × Kv, so Kv = Cv / 1.156. Kvs is the full-open Kv listed in the catalogue.
Formulas
- Kv = Q · √(SG / ΔP)
- Q = Kv · √(ΔP / SG)
- Cv = 1.156 · Kv
- Kv = 0.04 · DN² / √ζ
Try the calculation
Size it: the Kv you need
- Kv
- 70.71 m³/h
- Cv
- 81.74
Kv = Q · √(SG / ΔP). Pick a valve whose Kv at its working opening is at least this. Pre-selection only: confirm with the manufacturer.
Convert Cv to Kv
Kv = Cv / 1.156 = 86.51 m³/h
6Why it matters, and common mistakes
Why it matters
- ✓Kv is how you size a valve: find the Kv you need, then pick a valve that has it.
- ✓It lets you compare valves from different makers on one scale.
- ✓Cv appears on US datasheets, so you will need to convert.
Common mistakes
- !Mixing up Kv and Cv: they differ by about 15%.
- !Using the full-open Kvs for a valve that will run partly open.
- !Forgetting the liquid: oil and brine do not flow like water.
Keep going: more essentials
Pipe sizes and pressure classes
DN, PN, flange ratings and end connections made simple.
Open lesson →
Cavitation
Why liquids form bubbles through a valve, and how that damages equipment.
Open lesson →
Water hammer
Pressure surges from fast valve closure, and how to avoid them.
Open lesson →
Reading P&IDs
Symbols and tags for valves, pumps and instruments on a piping diagram.
Open lesson →
Torque
The twisting force that turns a valve stem, a bolt or a shaft.
Open lesson →