Nozzle check valves
A spring-loaded plug that slides along the pipe and shuts before the flow can turn back.
1What a nozzle check valve is
A nozzle (axial) check valve lets fluid pass one way only. A streamlined plug sits on a narrowing seat, the nozzle, in the middle of the body. The flow pushes the plug a short way downstream and passes round it. A coil spring pushes it back onto the seat as soon as the flow slows, before it can reverse. The plug moves along the pipe, not across it, so the valve closes very fast and almost without a bang.
Imagine it
Think of the plunger of a bicycle pump valve, or a spring-loaded cork in a bottle. Push on it from one side and it lifts. Let go and the spring puts it back at once.
- Movement
- A plug slides about a quarter of the bore along the pipe axis
- Main job
- Stop reverse flow with the least slam of any check valve
- Typical size and rating
- DN 50 to DN 2000 and more, to Class 900 and above
- Controlled by
- The flow and a spring: nothing outside moves it
2Watch it work
Slide the flow to push the plug downstream, then take the flow away. Watch the spring push the plug back on its seat and the pressure gauges change.
- 1Forward flow pushes on the nose of the plug and slides it downstream against the spring.
- 2The fluid passes through the ring-shaped gap round the plug, and the smooth shape keeps the loss low.
- 3When the flow slows, the spring pushes the plug back at once. It has only a short way to go.
- 4If the flow tries to reverse, the pressure presses the plug on to the seat and seals it.
3How it was invented
Six steps took it from a plain poppet to the streamlined valve used on fast pump trips.
1 / 6
The poppet
Early 1900s
A plug that lifts and falls
The first axial checks were plain poppets: a blunt disc on a stem that lifted with the flow and fell back by its own weight or by the reverse flow. They only worked when mounted the right way up.
The problem
A poppet that closes by weight alone closes late.
The answer
Give it something that pushes it shut.
4The idea behind it
A nozzle check valve is built on a few simple ideas.
A short stroke
The plug moves only about a quarter of the bore. It has almost no distance to travel when it closes, so it shuts in a fraction of a second.
A spring does the closing
The spring pushes the plug back the moment the flow slows. It does not depend on gravity, so the valve can be fitted in any position.
A smooth path
The nozzle narrows the flow and the plug is streamlined, so the fluid passes with little turbulence and little loss.
Pressure seals it
Once it is shut, the pressure from the high side presses the plug harder on to the seat. The higher the back pressure, the tighter it seals.
What you gain
- ✓The lowest slam of the check valves: it shuts before the flow reverses.
- ✓Works in any position, horizontal or vertical.
- ✓A smooth, low-loss path and a long life, because nothing swings or flutters.
- ✓Suited to fast pump stops, gas lines and critical duties.
What you pay
- !A longer and heavier body than a wafer check.
- !Not for solids, sewage or slurry: they jam the guide and the stem.
- !The spring needs enough flow to hold the plug open, so the valve is chosen for the flow.
- !Often dearer than a swing check, especially in large sizes.
5How it compares
The usual check valves, side by side.
| Valve | Opening | Loss when open | Slam | Best use |
|---|---|---|---|---|
| Nozzle (axial) | Spring-loaded plug slides along the flow | Medium | Lowest: non-slam | Fast pump trips, gas and critical lines |
| Dual-plate (wafer) | Two spring plates fold | Medium | Low: spring-closed | Compact pump discharge lines |
| Swing check | Hinged disc swings aside | Low | Can slam in long lines | Water, sewage and general pump lines |
| Tilting disc | Disc tips on an offset pivot | Low | Low: closes early | Large pump discharge lines |
| Lift check / ball check | Disc or ball lifts straight | High | Low | Pulsating flow, small sizes, steam |
Typical, general guidance. A manufacturer's datasheet decides the final choice.