Nozzle check valves
A spring-loaded plug that slides along the pipe and shuts before the flow can turn back.
Learn sizing
Seven short lessons take you from "is a nozzle check right for my line?" to a finished selection. Each has a drawing and a calculator you can play with. Nothing here is saved or sent.
1Is a nozzle check the right check valve?
A nozzle check is the first choice for clean lines that must stop fast without a bang. It is not for solids or sewage, and not where space is very tight.
- ✓Clean water, gas and oil on pump discharge lines: yes.
- ✓Fast pump trips: yes, the plug seats before the flow reverses.
- ✓Sewage, slurry and rags: no, use a swing check.
- ✓Where space is tight: a dual-plate wafer is shorter.
A nozzle check with a standard spring.
Try it
Fluid
A nozzle check closes with the least slam of any check valve, because the plug has only a short way to go.
💡 Ask first whether the fluid is clean and how fast the pump can stop. A nozzle check earns its price on the fastest stops.
2How the plug slides
The flow pushes the nose of the plug and slides it downstream along its stem. The fluid passes through the ring-shaped gap between the plug and the body. The spring pushes the plug back when the flow slows.
- ✓The plug moves about a quarter of the bore.
- ✓The stem runs in a bush, so the plug stays straight.
- ✓A double guide holds the nose as well.
- ✓The stroke is short, so the plug closes very fast.
Single guide
Double guide
Left: single guide. Right: double guide.
Try it
- Velocity
- 2.65 m/s
- Minimum velocity to hold it open
- 1.39 m/s
- How far the plug is held open
- 100 %
- ζ
- 1.90
OKThe flow is enough to hold the plug fully open.
The rule of thumb is v = 36·√V in ft/s for a standard spring, where V is the specific volume. A lighter spring holds the plug open at a lower speed; a heavier one needs more.
💡 Use the sliders to see that the plug only opens fully if the flow is above the holding speed.
3Loss and size
The nozzle and the streamlined plug keep the flow smooth, so the loss is lower than in a dual-plate. The loss is still higher than in a clear-bore swing check, because the plug stays in the flow.
- ✓The loss is a number ζ times the velocity head.
- ✓A double guide adds a little loss.
- ✓Size the valve for the flow, not just the pipe.
- ✓A smaller valve than the pipe is common.
ΔP = ζ · ρ · v² / 2 Kv = 0.04 · DN² / √ζ
The same line with three bodies.
Try it
- Velocity
- 1.77 m/s
- Flanged
- ζ 1.90 · ΔP 0.030 bar
- Wafer
- ζ 2.30 · ΔP 0.036 bar
- Welded
- ζ 1.90 · ΔP 0.030 bar
Typical figures. A wafer body is short and compact; a flanged body is longer and loses a little less. A welded body is the same inside as a flanged one.
💡 A valve one size smaller than the pipe often holds the plug open better and costs less.
4Body, parts and rating
A nozzle check is built with flanges, as a wafer, or with weld ends. Know the parts and you can read any datasheet. The rating is the highest pressure at a given temperature.
- ✓Flanged: every size, easy to remove.
- ✓Wafer: short and light, for small sizes and low pressure.
- ✓Welded: high pressure and buried lines.
- ✓The rating comes from the body and the seat together.
Typical – not brand data. Materials vary by manufacturer, size, class and service.
Every part of the valve, with its typical material in the list below.
Try it
Class 300 (39.8 bar)
Resilient seats usually limit the class: EPDM and NBR seats are normally used up to Class 300.
💡 Check the maker's pressure-temperature table: a rubber seat usually limits the class to 300 and about 100 °C.
5Seats and trim
The seat is where the valve seals. A rubber ring seals drop-tight but suits only some fluids and temperatures. The plug, stem and bush are wet by the fluid, so they must resist it.
- ✓Metal seat: hot fluids, a small leak.
- ✓Rubber seat: water and cold fluids, drop-tight.
- ✓Bronze fails in seawater and steam.
- ✓316 or duplex for chloride.
A valve with a rubber ring on the plug.
Try it
- Metal (13 % chrome or bronze)Suited
- Hard-faced metalSuited
- EPDM rubberSuited
- NBR (nitrile)Suited
- FKM (fluoroelastomer)Not suitednot suited to this fluid
A rubber seat seals drop-tight but is limited in temperature and fluid. A metal seat takes the heat but leaks a little.
💡 Choose the seat for the fluid first, then the temperature, then the pressure.
6Slam and the closing surge
When the pump stops, the flow slows, stops and then runs back. A plug that is still open when the flow reverses is slammed shut, and the sudden stop sends a pressure wave along the pipe. The nozzle check's plug has only a short way to go, so there is almost no reverse flow.
- ✓The longer and the lower the pressure, the slower the flow stops.
- ✓A plug that closes sooner has less reverse flow.
- ✓A heavier spring closes even sooner.
- ✓Always check this for pump lines with liquids.
a = (P / ρ) / L (not above v / 0.5) v_rev = a · t_close ΔP = ρ · c · v_impact
A standard spring.
Try it
- How fast the flow slows
- 2.00 m/s²
- Time for the plug to shut
- 0.03 s
- Velocity at impact
- 0.04 m/s
- Closing surge
- 0.4 bar
OKThe surge is within the allowed value.
💡 A nozzle check usually keeps the surge well under the limit, even on a long line.
7Choosing the spring
A light spring holds the plug open at a low flow but closes it more slowly. A heavy spring closes it fastest but needs more flow to hold open. Pick the lightest spring that keeps the surge within the allowed value, and check that your flow still holds the plug open.
- ✓Light: low flows and low pressure.
- ✓Standard: most pump lines.
- ✓Heavy: fast stops and long pump lines.
- ✓Check the flow at your normal duty as well as the trip.
Light spring
Heavy spring
Left: light spring. Right: heavy spring.
Try it
- Light spring0.4 barOKMinimum velocity to hold it open: 1.11 m/s
- Standard spring0.3 barOKMinimum velocity to hold it open: 1.39 m/s
- Heavy spring0.2 barOKMinimum velocity to hold it open: 1.74 m/s
Each spring is set against the allowed closing surge. A heavy spring needs more flow to hold the plug open, so check that too.
💡 Choose the spring for the worst case: a pump trip, not a gentle stop, but check the flow at your normal duty too.
Ready to size your valve?
Enter your duty once and the next pages decide if a nozzle check suits it, choose the guide, spring and body, pick the seat and materials, read off the rating, and check flow, holding velocity and closing surge.
Start with the duty →