1Hazen–Williams equation
The water-pipe friction formula many standards still use.
2The law in plain words, and a picture to remember
The Hazen–Williams equation estimates the friction loss of water in a full pipe from the flow, the diameter, the length and a roughness coefficient C: h_f = 10.67 · L · Q^1.852 / (C^1.852 · D^4.87). A higher C means a smoother pipe and less loss. It is simpler than Darcy–Weisbach but only valid for water in ordinary conditions.
Imagine it
Think of a delivery driver on two routes: a smooth new motorway and an old, potholed road. The motorway has a high C: lots of speed for little effort. The old road has a low C: the same speed costs far more. The formula puts one number on the condition of the road.
Memory hook
Higher C, smoother pipe, less loss. Pipes age and C falls: a drop from 140 to 100 costs about 1.9 times the friction.
3What it depends on, and how
Three things set the loss in the formula.
Roughness coefficient C
It depends on the pipe material and its age.
New plastic about 150, new steel about 140, old cast iron about 100.
h_f ∝ 1 / C^1.852
Flow
The loss rises a little less than the square of the flow.
Double the flow, about 3.6 times the loss.
h_f ∝ Q^1.852
Diameter
The strongest effect: the loss falls very fast as the pipe gets wider.
Doubling the diameter cuts the loss about 29 times.
h_f ∝ 1 / D^4.87
Try it: compare Hazen–Williams with Darcy–Weisbach for the same pipe
A water main ages and its C falls from 140 to 100. How much more friction loss does it have at the same flow?
- Hazen–Williams loss per 100 m
- 0.317 bar
- Darcy–Weisbach loss per 100 m
- 0.311 bar
- Speed
- 2.36 m/s
- Hazen–Williams compared with Darcy–Weisbach
- +2 %
Inside the formula's range: water, turbulent flow, speed up to 3 m/s. The two methods agree about as well as their usual scatter.
5Formula and units
SI form: L in m, Q in m³/s, D in m, result in m of water. The lesson shows Q in m³/h, D in mm and results in bar per 100 m of pipe. C has no unit and is not a physical property: it is a fitted number.
Formulas
- h_f = 10.67 · L · Q^1.852 / (C^1.852 · D^4.87)
- C: 150 plastic, 140 new steel, 120 used steel, 100 old cast iron
- valid: water at 5 to 25 °C, turbulent, D ≥ 50 mm, v ≤ 3 m/s
6Why it matters, and common mistakes
Why it matters
- ✓Fire-protection, irrigation and water-main design standards use it.
- ✓It gives a quick hand check of a water line.
- ✓It shows how pipe ageing raises the pumping cost.
Common mistakes
- !Using it for oil, hot water, steam or gas: the coefficient C does not cover viscosity.
- !Using it for small pipes or very high speeds, outside its range.
- !Treating C as exact: it is a fitted number that varies with age and condition.
Keep going: more engineering laws
Law of continuity
What flows in must flow out: A₁v₁ = A₂v₂.
Open lesson →
Bernoulli's principle
Faster flow means lower pressure. Energy is traded, not lost.
Open lesson →
Pascal's law and hydrostatics
Pressure in a still fluid grows with depth: P = ρgh.
Open lesson →
Darcy–Weisbach equation
How much pressure a pipe eats through friction.
Open lesson →
Newton's law of viscosity
Shear stress is viscosity times velocity gradient.
Open lesson →
Ideal gas law
Pressure, volume and temperature of a gas: PV = nRT.
Open lesson →
Torricelli and orifice flow
Flow through an opening from the pressure or head behind it.
Open lesson →
Pump affinity laws
How pump flow, head and power change with speed.
Open lesson →