1Hazen–Williams equation

The water-pipe friction formula many standards still use.

2The law in plain words, and a picture to remember

In plain words

The Hazen–Williams equation estimates the friction loss of water in a full pipe from the flow, the diameter, the length and a roughness coefficient C: h_f = 10.67 · L · Q^1.852 / (C^1.852 · D^4.87). A higher C means a smoother pipe and less loss. It is simpler than Darcy–Weisbach but only valid for water in ordinary conditions.

Imagine it

Think of a delivery driver on two routes: a smooth new motorway and an old, potholed road. The motorway has a high C: lots of speed for little effort. The old road has a low C: the same speed costs far more. The formula puts one number on the condition of the road.

Memory hook

Higher C, smoother pipe, less loss. Pipes age and C falls: a drop from 140 to 100 costs about 1.9 times the friction.

3What it depends on, and how

Three things set the loss in the formula.

1

Roughness coefficient C

It depends on the pipe material and its age.

New plastic about 150, new steel about 140, old cast iron about 100.

h_f ∝ 1 / C^1.852

2

Flow

The loss rises a little less than the square of the flow.

Double the flow, about 3.6 times the loss.

h_f ∝ Q^1.852

3

Diameter

The strongest effect: the loss falls very fast as the pipe gets wider.

Doubling the diameter cuts the loss about 29 times.

h_f ∝ 1 / D^4.87

Try it: compare Hazen–Williams with Darcy–Weisbach for the same pipe

A water main ages and its C falls from 140 to 100. How much more friction loss does it have at the same flow?

0.000.501.001.502.000100200300400Flow (m³/h)Friction loss (bar per 100 m)Hazen–WilliamsDarcy–Weisbach
Hazen–Williams loss per 100 m
0.317 bar
Darcy–Weisbach loss per 100 m
0.311 bar
Speed
2.36 m/s
Hazen–Williams compared with Darcy–Weisbach
+2 %

Inside the formula's range: water, turbulent flow, speed up to 3 m/s. The two methods agree about as well as their usual scatter.

5Formula and units

SI form: L in m, Q in m³/s, D in m, result in m of water. The lesson shows Q in m³/h, D in mm and results in bar per 100 m of pipe. C has no unit and is not a physical property: it is a fitted number.

Formulas

  • h_f = 10.67 · L · Q^1.852 / (C^1.852 · D^4.87)
  • C: 150 plastic, 140 new steel, 120 used steel, 100 old cast iron
  • valid: water at 5 to 25 °C, turbulent, D ≥ 50 mm, v ≤ 3 m/s

6Why it matters, and common mistakes

Why it matters

  • ✓Fire-protection, irrigation and water-main design standards use it.
  • ✓It gives a quick hand check of a water line.
  • ✓It shows how pipe ageing raises the pumping cost.

Common mistakes

  • !Using it for oil, hot water, steam or gas: the coefficient C does not cover viscosity.
  • !Using it for small pipes or very high speeds, outside its range.
  • !Treating C as exact: it is a fitted number that varies with age and condition.