1Torricelli and orifice flow

Flow through an opening from the pressure or head behind it.

2The law in plain words, and a picture to remember

In plain words

Torricelli's law says that liquid leaves an opening below the surface at the speed it would reach in free fall from the surface: v = √(2gh). The flow is that speed times the area of the opening, reduced by a discharge coefficient Cd because the jet narrows: Q = Cd · a · √(2gh). With a pressure difference instead of a height, v = √(2ΔP/ρ).

Imagine it

Poke holes in a bottle of water. Near the top the water dribbles. Near the bottom it shoots out. The deeper the hole, the more water sits above it, pushing. And as the bottle empties, the jet weakens and lands closer.

Memory hook

Speed = √(2gh): four times the depth, twice the speed. Pressure works the same way: v = √(2ΔP/ρ).

3What it depends on, and how

Three things set the flow through an opening.

1

Depth or pressure

The push behind the opening.

Four times the depth gives twice the speed.

v = √(2 · g · h)

2

Opening size

The flow is the speed times the area.

Double the hole diameter, four times the flow.

Q = Cd · a · v

3

Discharge coefficient

The jet narrows just after the opening (the vena contracta), so the real flow is less than the ideal.

Cd is about 0.6 for a sharp hole and up to 0.98 for a well-rounded nozzle.

Cd ≈ 0.6 to 0.98

Try it: open a hole in a tank and watch the jet and the level

Water leaves a hole in a tank. The water above the hole becomes four times deeper. What happens to the speed of the jet?

h = 1.60 m1.96 m
Jet speed
5.60 m/s
Flow
1.09 L/s
Range of the jet
1.96 m
Time to empty down to the hole (real time)
48.9 min

The jet is fastest when the water above the hole is deep. As the tank drains, it weakens and lands closer.

5Formula and units

Depth in m, speed in m/s, areas in m². Q comes out in m³/s (multiply by 1000 for L/s, or by 3600 for m³/h). For a pressure difference use v = √(2ΔP/ρ) with ΔP in Pa.

Formulas

  • v = √(2 · g · h)
  • Q = Cd · a · √(2 · g · h)
  • Q = Cd · a · √(2 · ΔP / ρ)
  • t_drain = (A / (Cd · a)) · √(2h / g)
  • range x = 2 · √(h · y)

6Why it matters, and common mistakes

Why it matters

  • ✓It sizes drain, vent and bleed openings, and orifice plates.
  • ✓It is the basis of orifice and nozzle flow measurement.
  • ✓It predicts how fast a tank empties and how a leak behaves.

Common mistakes

  • !Forgetting the discharge coefficient and overestimating the flow.
  • !Using the tank height instead of the depth above the hole.
  • !Applying it to a pressurised tank without adding the pressure term.