1Pump affinity laws
How pump flow, head and power change with speed.
2The law in plain words, and a picture to remember
The pump affinity laws say how a centrifugal pump behaves when its speed changes: flow changes in proportion to the speed, head with its square and power with its cube. The same laws apply to changes of impeller diameter. They hold exactly between similar operating points of the same pump.
Imagine it
Think of a fan. Run it at half speed and you get about half the airflow. But the push you feel falls to a quarter, and the electricity it draws falls to an eighth. A little speed is worth a lot of energy, so a small slowdown saves a great deal.
Memory hook
Flow ∝ N, head ∝ N², power ∝ N³. A 20% slowdown saves about 49% of the power.
3What it depends on, and how
Three things decide how the laws apply.
Speed
It scales the whole pump curve.
At 80% speed: 80% flow, 64% head and 51% power.
Q ∝ N, H ∝ N², P ∝ N³
Impeller diameter
Trimming the impeller scales the curve in the same way.
A 10% smaller impeller gives about 10% less flow and 19% less head.
Q ∝ D, H ∝ D²
The system
The pump runs where its curve meets the system curve, so a system with static head moves the point differently.
The laws are exact for friction-only systems.
similar points
Try it: change the pump speed and watch flow, head and power
A pump's speed is cut by 20%. By roughly how much does the power it uses drop?
Flow
80 %
Head
64 %
Power
51 %
Power × 0.51 compared with full speed
- Flow
- 109 m³/h
- Power with speed control
- 7.2 kW
- Power to get the same flow by throttling
- 13.9 kW
- Saved by slowing the pump instead of throttling
- 48 %
A slower pump: the power falls by about 49%, far more than the speed.
5Formula and units
Speed N in rpm (or percent), flow in m³/h, head in m, power in kW. The laws use ratios, so any consistent unit works.
Formulas
- Q₂ / Q₁ = N₂ / N₁
- H₂ / H₁ = (N₂ / N₁)²
- P₂ / P₁ = (N₂ / N₁)³
- Q ∝ D, H ∝ D², P ∝ D³ (impeller trim)
6Why it matters, and common mistakes
Why it matters
- ✓They predict the effect of a variable-speed drive before you buy it.
- ✓They explain why throttling wastes power and slowing the pump saves it.
- ✓They let you scale a pump curve to a new speed or impeller.
Common mistakes
- !Expecting the power saving to be proportional to the speed cut.
- !Applying them far from the best-efficiency point or to a system with a large static head.
- !Ignoring that motor and drive efficiency change at low speed.
Keep going: more engineering laws
Law of continuity
What flows in must flow out: A₁v₁ = A₂v₂.
Open lesson →
Bernoulli's principle
Faster flow means lower pressure. Energy is traded, not lost.
Open lesson →
Pascal's law and hydrostatics
Pressure in a still fluid grows with depth: P = ρgh.
Open lesson →
Darcy–Weisbach equation
How much pressure a pipe eats through friction.
Open lesson →
Newton's law of viscosity
Shear stress is viscosity times velocity gradient.
Open lesson →
Ideal gas law
Pressure, volume and temperature of a gas: PV = nRT.
Open lesson →
Torricelli and orifice flow
Flow through an opening from the pressure or head behind it.
Open lesson →
Hazen–Williams equation
The water-pipe friction formula many standards still use.
Open lesson →