The question it answers
Classification by air valve type
How much air, and which way?
Air in a pipeline is a nuisance. It forms pockets that choke the flow, and when a pipe drains, air must come in or the pipe can collapse. Different air valves handle small pockets, large volumes, or both.
1The options in detail
Air release valve
Releases small pockets of air while the pipe is working.
How it works
Air gathers at the high point and pushes the water level in the valve down, so the float falls and opens a tiny orifice. The air escapes against the system pressure. When water returns, the float rises and shuts the orifice.
Strengths
- ✓Works while the pipe is under pressure.
- ✓Removes air that comes out of solution.
- ✓Small and cheap.
Limits
- !Too small to vent a filling pipe quickly.
- !Cannot admit air.
Where it is used
- •Pressurised pipelines.
- •Pump discharge lines.
Kinetic (large orifice) valve
Vents and admits large volumes of air quickly.
How it works
A large orifice lets air out as the pipe fills, and in as it drains. The float shuts the orifice when water arrives. It cannot open against pressure, so it only acts while filling and draining.
Strengths
- ✓Large air flow.
- ✓Protects against vacuum when draining.
- ✓Fast filling.
Limits
- !Does not release air under pressure.
- !Can slam if the water arrives fast.
Where it is used
- •Filling and emptying pipelines.
- •High points.
Combination valve
Both duties in one body.
How it works
A large float handles filling and draining, and a small one releases air while the pipe is pressurised. One valve covers all three jobs.
Strengths
- ✓Covers all the air duties.
- ✓Fewer valves to install.
- ✓A good default.
Limits
- !Costs more.
- !Needs a drain for cleaning.
Where it is used
- •Main high points.
- •Pump stations.
How to choose
- →Air that creeps out of solution: air release valve.
- →Filling and draining long pipelines: kinetic valve.
- →Not sure: a combination valve at high points.
Common mistakes
- !Using only small-orifice valves on a pipeline that must be filled and drained.
- !Fitting air valves without an isolation valve for maintenance.
- !Forgetting that an air valve at a low point does nothing.