The question it answers
Classification by reducing valve design
How does it hold the lower pressure?
A pressure-reducing valve holds the pressure after it steady, even when the pressure before it, or the demand after it, changes. It does this by throttling the flow.
1The options in detail
Direct-acting
The downstream pressure acts directly on a diaphragm against a spring.
Outlet pressure: 6.00 bar (set 4.0)Drag to rotate · hover a dot for its name
How it works
Downstream pressure on the diaphragm pushes the plug toward closing; the spring pushes it open. When demand rises, the downstream pressure sags and the spring opens the valve. When demand falls, the pressure rises and the plug closes. A small droop appears between low and high flow.
Strengths
- ✓Simple.
- ✓No piping around it.
- ✓Self-contained.
Limits
- !The pressure droops with flow.
- !Limited accuracy.
Where it is used
- •House supply.
- •Small steam and air systems.
Pilot-operated
A small pilot valve senses the pressure and a large main valve does the work.
Outlet pressure: 6.00 bar (set 4.0)Drag to rotate · hover a dot for its name
How it works
The pilot reads the downstream pressure and sets the pressure in the dome above the main piston. More dome pressure closes the main valve; less opens it. The loading is strong, so the valve holds its set pressure closely over a wide flow range.
Strengths
- ✓Accurate.
- ✓Large flows.
- ✓Little droop.
Limits
- !The pilot can clog on dirty fluid.
- !More parts.
Where it is used
- •District water supply.
- •Large steam lines.
How to choose
- →Small, simple duties: direct-acting.
- →Large flows and tight pressure: pilot-operated.
- →Dirty water: direct-acting, or a strainer upstream.
Common mistakes
- !Oversizing a reducing valve: it works almost closed and hunts.
- !No relief valve downstream when the valve could fail open.
- !Leaving out the strainer in front of a pilot-operated valve.