The question it answers
Classification by relief valve design
How does the valve know when to open?
Every relief valve must open at a set pressure and close again once it is safe. How it manages that matters when the pressure behind its outlet changes, or when the valve is large.
1The options in detail
Direct spring-loaded
A spring holds the disc shut until the pressure under it wins.
How it works
An adjusting screw sets the spring force. At the set pressure the disc lifts and the valve pops open. It re-seats when the pressure has fallen a few percent below the set value. The pressure at the outlet adds to the spring, so back pressure raises the opening pressure.
Strengths
- ✓Simple and reliable.
- ✓No pilot or supply needed.
- ✓Opens fast.
Limits
- !Back pressure shifts the set point.
- !Can chatter if inlet losses are large.
Where it is used
- •Boilers.
- •Small vessels and pumps.
Balanced bellows
A bellows cancels the effect of back pressure.
How it works
A metal bellows has the same area as the seat. Back pressure acts on both the disc and the bellows, so the forces cancel, and the valve opens at its set pressure whatever the pressure in the discharge system. The bonnet is vented.
Strengths
- ✓Set point is not changed by back pressure.
- ✓Protects the spring from the fluid.
- ✓Good for corrosive fluids.
Limits
- !The bellows can fail.
- !Costs more.
Where it is used
- •Flare headers.
- •Chemical plants.
Pilot-operated
A small pilot valve controls a large main valve.
How it works
System pressure is also fed to a dome above a piston on the main valve, which holds it shut. At the set pressure the pilot vents the dome, so the pressure under the disc lifts it fully. The closing force rises with the pressure, so the seal is better than a spring can give.
Strengths
- ✓Tight seal close to the set pressure.
- ✓Large capacity.
- ✓Accurate set point.
Limits
- !The pilot can clog on dirty fluids.
- !More complex.
Where it is used
- •Large vessels and pipelines.
- •Clean gas and liquids.
How to choose
- →Simple, small or dirty service: direct spring-loaded.
- →High or varying back pressure: balanced bellows.
- →Large capacity and a tight seal: pilot-operated.
Common mistakes
- !Ignoring back pressure on a conventional valve.
- !Using a pilot-operated valve on a dirty fluid.
- !Sizing for flow but forgetting inlet pressure loss, which makes the valve chatter.