The question it answers
Classification by what it protects against
What danger is the valve guarding against?
Protection valves watch for a danger and act by themselves. Some stop too much pressure building up, some stop too much pressure getting downstream, and some deal with air, which can block a pipe or leave it in a vacuum. What a valve does depends on what it guards against.
1The options in detail
Pressure relief and safety valve
Opens when the pressure goes above a set value, to release the excess.
How it works
A spring pushes a disc onto a seat. When the pressure rises to the set value, the force under the disc beats the spring and the valve opens to discharge. When the pressure falls, the spring closes it again.
Strengths
- ✓Works without power.
- ✓The last line of defence.
- ✓Simple.
Limits
- !Must be tested regularly.
- !Its discharge must go somewhere safe.
Where it is used
- •Boilers and pressure vessels.
- •Pumps and pipelines.
Pressure-reducing valve
Holds a lower, steady pressure downstream.
Outlet pressure: 6.00 bar (set 4.0)Drag to rotate · hover a dot for its name
How it works
The downstream pressure acts on a diaphragm against a spring. If it falls, the spring opens the valve; if it rises, the diaphragm closes it. The valve holds its set pressure whatever the supply does.
Strengths
- ✓Steady downstream pressure.
- ✓Protects equipment and pipes.
- ✓No power needed.
Limits
- !Needs flow to work well.
- !Can leak when closed.
Where it is used
- •Water supply to buildings.
- •Steam and gas.
Air valve
Lets air out when a pipe fills and in when it drains.
How it works
A float rises with the water and seals the orifice. When air collects, the float drops and the orifice opens to release it. When the pipe drains, the valve opens to let air in, which avoids vacuum damage.
Strengths
- ✓Prevents air locks.
- ✓Protects against vacuum.
- ✓No power needed.
Limits
- !Needs checking for blockage.
- !Must sit at high points.
Where it is used
- •Water mains.
- •Pumping lines.
How to choose
- →Over-pressure from heat or a blocked outlet: relief valve.
- →Supply pressure too high for the system: reducing valve.
- →Pipeline with high points: air valves.
Common mistakes
- !Thinking a relief valve is a control valve: it is only a safety device.
- !Putting a relief valve where its discharge can hurt people.
- !Leaving out air valves at high points.