1NPSH

Whether a pump has enough pressure at its inlet to avoid cavitation.

2Easy definition, and a picture to remember

In plain words

NPSH stands for net positive suction head. NPSH available (NPSHa) is how much pressure above the vapour pressure the liquid has when it reaches the pump inlet, in metres of liquid. NPSH required (NPSHr) is what the pump needs from the maker's curve. The pump is safe only while NPSHa is bigger than NPSHr, with a margin.

Imagine it

A pump does not push liquid in, it pulls: it lowers the pressure at its inlet, and the atmosphere (or the tank) pushes liquid in to fill the gap. If the pressure at the inlet falls to the point where the liquid boils, bubbles form, and the pump chokes on vapour. NPSH is how far you are from that edge.

Memory hook

NPSHa must stay above NPSHr, with a margin. Heat, suction lift and long suction pipes all reduce NPSHa.

3What decides it, and how

Three things set the NPSH available.

1

Liquid level (lift)

A liquid level above the pump pushes the liquid in. A level below it makes the pump pull it up.

Each metre of lift takes a metre off NPSHa.

NPSHa = … + z

2

Temperature

Hot liquid has a high vapour pressure and so is close to boiling already.

Water at 20 °C leaves about 10 m of NPSH from an open tank. At 90 °C only about 3 m.

Pv rises with T

3

Suction friction and flow

Pipe, strainer and fittings on the suction side lose head, and they lose more at higher flow.

Doubling the flow quadruples the friction loss. NPSHr rises with flow too.

h_f = k · Q²

Try it: raise the water temperature or lower the tank and watch the margin

Hot water at 90 °C is pumped from an open tank. Why is cavitation more likely than with cold water?

Open tankdischargepump centre line+2.0 m
051015200100200300Flow (m³/h)NPSH (m)NPSHaNPSHr

NPSHa

11.0 m

NPSHr

6.0 m

Margin (NPSHa − NPSHr)

+5.0 m

A comfortable margin: the pump has enough pressure at its inlet.

5Units and formulas

NPSH is in metres of the pumped liquid. Convert pressure to head by dividing by ρg: 1 bar of water is about 10.2 m. P and Pv must both be absolute.

Formulas

  • NPSHa = (P − Pv) / (ρ · g) + z − h_f
  • NPSHa > NPSHr + margin (0.5 m or more)
  • max suction lift ≈ (Patm − Pv) / (ρ · g) ≈ 10 m for cold water

6Why it matters, and common mistakes

Why it matters

  • ✓Cavitating pumps lose flow and head, make noise and destroy impellers.
  • ✓It limits how high a pump can lift from a tank, and how hot the liquid can be.
  • ✓It is the first check when a pump is far from its tank or the liquid is warm.

Common mistakes

  • !Using gauge pressure instead of absolute pressure.
  • !Forgetting suction friction, strainers and fittings.
  • !Taking NPSHr at the best-efficiency flow when the pump will run far to the right.