1NPSH
Whether a pump has enough pressure at its inlet to avoid cavitation.
2Easy definition, and a picture to remember
NPSH stands for net positive suction head. NPSH available (NPSHa) is how much pressure above the vapour pressure the liquid has when it reaches the pump inlet, in metres of liquid. NPSH required (NPSHr) is what the pump needs from the maker's curve. The pump is safe only while NPSHa is bigger than NPSHr, with a margin.
Imagine it
A pump does not push liquid in, it pulls: it lowers the pressure at its inlet, and the atmosphere (or the tank) pushes liquid in to fill the gap. If the pressure at the inlet falls to the point where the liquid boils, bubbles form, and the pump chokes on vapour. NPSH is how far you are from that edge.
Memory hook
NPSHa must stay above NPSHr, with a margin. Heat, suction lift and long suction pipes all reduce NPSHa.
3What decides it, and how
Three things set the NPSH available.
Liquid level (lift)
A liquid level above the pump pushes the liquid in. A level below it makes the pump pull it up.
Each metre of lift takes a metre off NPSHa.
NPSHa = … + z
Temperature
Hot liquid has a high vapour pressure and so is close to boiling already.
Water at 20 °C leaves about 10 m of NPSH from an open tank. At 90 °C only about 3 m.
Pv rises with T
Suction friction and flow
Pipe, strainer and fittings on the suction side lose head, and they lose more at higher flow.
Doubling the flow quadruples the friction loss. NPSHr rises with flow too.
h_f = k · Q²
Try it: raise the water temperature or lower the tank and watch the margin
Hot water at 90 °C is pumped from an open tank. Why is cavitation more likely than with cold water?
NPSHa
11.0 m
NPSHr
6.0 m
Margin (NPSHa − NPSHr)
+5.0 m
A comfortable margin: the pump has enough pressure at its inlet.
5Units and formulas
NPSH is in metres of the pumped liquid. Convert pressure to head by dividing by ρg: 1 bar of water is about 10.2 m. P and Pv must both be absolute.
Formulas
- NPSHa = (P − Pv) / (ρ · g) + z − h_f
- NPSHa > NPSHr + margin (0.5 m or more)
- max suction lift ≈ (Patm − Pv) / (ρ · g) ≈ 10 m for cold water
6Why it matters, and common mistakes
Why it matters
- ✓Cavitating pumps lose flow and head, make noise and destroy impellers.
- ✓It limits how high a pump can lift from a tank, and how hot the liquid can be.
- ✓It is the first check when a pump is far from its tank or the liquid is warm.
Common mistakes
- !Using gauge pressure instead of absolute pressure.
- !Forgetting suction friction, strainers and fittings.
- !Taking NPSHr at the best-efficiency flow when the pump will run far to the right.
Keep going: more on valves and systems
Flow characteristics
How flow changes as a valve opens: linear, equal percentage and quick opening.
Open lesson →
Valve authority and rangeability
How much of the system pressure drop the valve controls, and how far it can turn down.
Open lesson →
Flashing and choked flow
When the flow stops rising however much the pressure drop grows.
Open lesson →
Minor losses (K factor)
What valves, bends and reducers cost in pressure.
Open lesson →
Pump and system curves
Where a pump and a pipe system balance: the operating point.
Open lesson →
Gas and steam flow
Compressible flow through a valve: expansion and the sonic limit.
Open lesson →
Control loop basics
Setpoint, gain, deadband and PID in plain words.
Open lesson →
Signals and fail-safe positions
4–20 mA, pneumatic signals, and what a valve does when power fails.
Open lesson →
Leakage classes and shut-off
What tight shut-off really means: how much a closed valve may leak.
Open lesson →
Noise and vibration
Why valves are loud, how sound adds up and fades, and what to do about it.
Open lesson →
Materials and corrosion
Choosing a valve body material that survives the fluid and the temperature.
Open lesson →