1Noise and vibration

Why valves are loud, how sound adds up and fades, and what to do about it.

2Easy definition, and a picture to remember

In plain words

Valves make noise because they turn pressure drop into turbulence. The faster and rougher the flow, the louder it is. Gas valves are the loudest, and cavitation in liquids sounds like gravel. Noise above about 85 dB(A) calls for hearing protection, and strong turbulence also shakes the pipe: that is vibration.

Imagine it

Put your thumb over a garden hose: the spray hisses, and the harder you squeeze the louder it gets. A valve does the same with a pipeline's pressure. The sound then spreads like ripples from a stone: each doubling of distance takes a few decibels off, and two valves together are only a little louder than one.

Memory hook

Doubling the distance takes 6 dB off. Doubling the number of valves adds only 3 dB. 85 dB(A) is where hearing protection starts.

3What decides it, and how

Three things set the sound level you hear.

1

Pressure drop and flow

More drop and more flow mean more turbulent energy.

Ten times the power in the flow is 10 dB louder.

ΔL = 10 · log₁₀(power ratio)

2

Distance

Sound spreads over a bigger area as it travels.

Every doubling of distance takes about 6 dB off in open air.

L₂ = L₁ − 20 · log₁₀(d₂ / d₁)

3

Number of sources and treatment

Equal sources add by 10 · log₁₀(n). Insulation, thicker pipe walls and low-noise trim take some off.

Two equal valves add just 3 dB. Heavy lagging can take several decibels off.

L = L₁ + 10 · log₁₀(n) − lagging

Try it: add valves, move away and wrap the pipe, and watch the level

Two identical valves each make 85 dB(A) at 1 m. How loud are both together at the same spot?

85 dB(A) @ 1 m85 dB(A)1 m2 m5 m10 m20 m50 m
40Limit 85 dB(A)120 dB(A)
Level at the listener
85.0 dB(A)
Combined noise at 1 m
85.0 dB(A) @ 1 m

Above 85 dB(A): hearing protection is needed, and the pipe is likely to vibrate. Reduce the drop, treat the source or move away.

5Units and formulas

Sound level in decibels, dB(A) for the A-weighted level that the ear hears. Distance in metres. Decibels are logarithmic: +3 dB is double the sound power, +10 dB is ten times, and +10 dB sounds about twice as loud.

Formulas

  • L₂ = L₁ − 20 · log₁₀(d₂ / d₁)
  • L = L₁ + 10 · log₁₀(n)
  • L_total = 10 · log₁₀(Σ 10^(Lᵢ/10))
  • Mach = v / c, c = √(k · R · T / M)

6Why it matters, and common mistakes

Why it matters

  • ✓Noise above 85 dB(A) is a health limit, and a common reason for rejecting a valve.
  • ✓It warns of cavitation, flashing or sonic flow that will also damage the valve.
  • ✓Strong turbulence shakes pipes and supports and causes fatigue cracks.

Common mistakes

  • !Adding decibels like ordinary numbers: 85 + 85 is 88, not 170.
  • !Quoting a level without the distance.
  • !Treating noise as only a comfort issue, when it also signals damage.