1Gas and steam flow

Compressible flow through a valve: expansion and the sonic limit.

2Easy definition, and a picture to remember

In plain words

A gas changes its density as its pressure changes, so it does not follow the simple liquid rule. As the gas drops in pressure across a valve it expands and speeds up. The flow rises with the pressure drop, but only up to a limit: when the speed at the valve's narrowest point reaches the speed of sound, no further drop makes it flow faster. That is choked (sonic) flow.

Imagine it

Imagine a crowd leaving a stadium through a narrow gate. People who are pushed from behind can only move as fast as the gate allows. Gas behaves the same way at the speed of sound: a pressure wave cannot travel upstream faster than that, so the news that the outlet pressure fell cannot get back to the gate. The flow stays where it is.

Memory hook

Gas: more drop, more flow, until the speed of sound at the throat. Then the flow depends on the inlet pressure only. Use the expansion factor Y, not the liquid formula.

3What decides it, and how

Three things decide how much gas a valve passes.

1

Pressure ratio

The flow depends on the drop as a share of the inlet pressure, x = ΔP / P₁, not on the drop alone.

Past x ≈ 0.7 a globe valve is choked: the flow no longer rises.

x = ΔP / P₁

2

The gas

Heavier gas flows less, and a gas with a lower ratio of specific heats chokes at a smaller ratio.

CO₂ passes about 80% of the air flow at the same conditions. Hydrogen passes almost four times more.

Q ∝ 1 / √M

3

Valve recovery (xT)

A valve that recovers more pressure chokes at a smaller ratio.

Typical xT: about 0.7 for a globe valve, about 0.4 for rotary valves.

x_choked = Fk · xT

Try it: sweep the pressure ratio and watch the flow reach the sonic limit

Gas flows through a valve with the outlet at 40% below the inlet pressure. You lower the outlet pressure almost to zero. What happens to the flow?

00.004,0000.258,0000.5012,0000.7516,0001.00Pressure-drop ratio x = ΔP / P₁Flow (Nm³/h)Sonic limit 0.72
Flow now
8,052 Nm³/h
Flow with the liquid-style formula
8,443 Nm³/h
Expansion factor Y
0.954
Choked (maximum) flow
15,103 Nm³/h

Free flow: the flow rises with the drop.

5Units and formulas

Pressures in bar absolute (kPa inside the IEC formula), temperature in K, molar mass M in kg/kmol. Flow is given at standard conditions, in normal cubic metres per hour (Nm³/h).

Formulas

  • Q = 24.6 · Kv · P₁ · Y · √(x / (M · T₁ · Z))
  • Y = 1 − x / (3 · Fk · xT)
  • x_choked = Fk · xT, Fk = k / 1.4
  • Y = 2/3 when choked

6Why it matters, and common mistakes

Why it matters

  • ✓Gas flow sizing differs from liquid sizing: the liquid formula overestimates the flow.
  • ✓Choked gas flow makes noise and sets the maximum flow of a valve.
  • ✓Pressure-reducing and venting valves on gas and steam lines depend on it.

Common mistakes

  • !Using the liquid formula with the density of gas.
  • !Using gauge pressure instead of absolute pressure.
  • !Ignoring the sonic limit and expecting more flow from a lower outlet pressure.

Keep going: more on valves and systems