1Flashing and choked flow

When the flow stops rising however much the pressure drop grows.

2Easy definition, and a picture to remember

In plain words

Lower the pressure after a valve and the flow rises, but only up to a limit. When the pressure at the valve's narrowest point reaches the liquid's vapour pressure, vapour fills the jet and blocks any further increase: the flow is choked. If the outlet pressure itself falls to the vapour pressure, the bubbles never collapse and the liquid flashes to vapour.

Imagine it

Drink through a straw and suck harder: the flow rises, until the liquid starts to boil in the straw and the bubbles get in the way. Suck harder still and you get no more drink. The valve's narrowest point is that straw.

Flows freelyThe drink rises faster the harder you suck.

Drink coming up

61 % of the most the straw can pass

ΔP_choked = FL² (P1 − FF·Pv) = 0.81 × (1.013 − 0.96 × 0.023) = 0.80 bar

The drink is cold water-like liquid at 20 °C. The most the straw can pass is the choked flow, where the pressure at the narrowest point falls to the vapour pressure of the liquid.

Memory hook

Choked: more pressure drop, same flow. Flashing: the outlet is below vapour pressure and the liquid turns to vapour for good.

3What decides it, and how

Three things set where choking begins.

1

Inlet pressure

A higher upstream pressure leaves more room before the jet hits the vapour pressure.

ΔP_choked rises almost in step with P₁.

ΔP_choked = FL² · (P₁ − FF · Pv)

2

Vapour pressure

Hotter liquid has a higher vapour pressure, so choking begins at a smaller drop.

With P₁ at 5 bar abs, water at 120 °C chokes at about 60% of the drop it takes at 20 °C.

Pv rises with T

3

Valve recovery (FL)

A valve that recovers a lot of pressure (low FL) has a lower pressure at its narrowest point, so it chokes sooner.

FL 0.6 chokes at less than half the drop of FL 0.9.

FL² in the choked limit

Try it: lower the outlet pressure and watch the flow flatten

The pressure after a valve is lowered more and more. What does the flow do?

01002003000246Pressure drop across the valve (bar)Flow (m³/h)Choked limit 6.5Liquid only
Flow now
100.0 m³/h
Flow if there were no choking
100.0 m³/h
Outlet pressure
7.00 bar abs
Choked (maximum) flow
254.2 m³/h

Liquid flow: the flow follows Kv and the square root of the drop.

5Units and formulas

Pressures in bar absolute, flow in m³/h. FL is a number between 0.5 and 1 listed for each valve. FF is the liquid critical pressure ratio factor, close to 0.96 for water.

Formulas

  • Q = Kv · √(ΔP / SG) below the limit
  • ΔP_choked = FL² · (P₁ − FF · Pv)
  • Q_max = Kv · FL · √((P₁ − FF · Pv) / SG)
  • FF = 0.96 − 0.28 · √(Pv / Pc)

6Why it matters, and common mistakes

Why it matters

  • ✓Sizing with a drop above the choked limit gives a valve that cannot pass the flow you expect.
  • ✓Choked and flashing flow damage trim and pipe: they set the choice of trim and material.
  • ✓It tells you when to split the drop across two valves or use a multistage trim.

Common mistakes

  • !Using the plain Kv formula with a drop above the choked limit.
  • !Using the gauge pressure instead of the absolute pressure in the limit.
  • !Ignoring a hot liquid: a high vapour pressure lowers the limit a lot.

Keep going: more on valves and systems